- Info
easYgen-1000
Flexible Single Unit Genset Control
The streamlined features of the easYgen-1000 turns this engine-generator control system into the ideal solution for your single unit application. With the flexible breaker control logic you can easily configure the easYgen-1000 for one of four operating modes - from a simple measuring transducer and engine control up to a full two-breaker, open-transition operation device. The simple automatic start/stop logic and automatic load transfer capabilities round out the features of the easYgen-1000 to cover all stand-by and emergency applications.
Features:
- FlexAppTM Technology
- Operation mode:
Auto, Manual, Test (load & no load) - Breaker configuration:
GCB and MCB - Breaker control:
Open-close control, only open control, breaker monitoring - Load transfer by open transition
- Start/stop logic for Diesel/gas engines
- LogicsManager to adapt programmable relays to your requirements
- Complete engine, generator, and mains protection with 3-phase true RMS AC sensing
- Multi-lingual capability: 10 languages
English, German, French, Italian, Spanish, Portugese, Russian, Turkish, Chinese, Japanese - Flexible and multifunctional Dynamic LCD
- True rms sensing of voltage with FlexRange
- True rms sensing of current/power
- kWh/kvarh meter
- Counters for engine starts, operating hours, maintenance call
- Event recorder (300 entries, FIFO) with real-time clock
- 8 discrete inputs / 11 discrete outputs
- 2 freely configurable analog inputs
- PC and/or front panel configurable
Communication:
- J1939 for ECU communication
- CANopen for external terminals (e.g. the IKD 1 extension card with up to 16 additional external I/Os)
- Woodward CAL protocol for configuration via PC and for the GW 4 gateway interface converter to communicate with PLCs
- Serial interfaces for configuration and interfacing with an external modem
Protection (generator/engine):
- Battery voltage
- Overspeed (ANSI# 12)
- Over/undervoltage (ANSI# 59/27)
- Over/underfrequency (ANSI# 81O/U)
- Overload (ANSI# 32)
- Reverse/reduced power (ANSI# 32R/F)
- Unbalanced load (ANSI# 46)
- Definite time-overcurrent (ANSI# 50/51)
- Inverse time-overcurrent (IEC 255)
- Calculated/measured ground fault
Typical application:

Certifications / registrations: UL/cUL, CE, GL, LR

Download Technical Documentation
1. To download technical documentation please register here first.
2. Already registered? Login here.
3. After successful login - return to this page and click here to start the download section.
Download LeoPC1 Configuration Files:
Refer to the configuration files download page for other P/Ns
Download LeoPC1 Configuration Program
Download GetEventLog Software
Top